Proposed CSV upload format
This is a proposed format for bulk uploading sensors. To be vetted and verified with Ensemble folks.
Sensor | Name | External ID | Latitude | Longitude | Reading_types | Depth | Brand | Model | Part_number | hardware_version |
---|---|---|---|---|---|---|---|---|---|---|
Description | How the sensor will be labelled in LiteFarm. | The sensor’s unique external id. This is the identity that will be used to register the sensor with external services and receive readings associated with this sensor. | The latitude for the sensor. | The longitude for the sensor. | Comma delimited list of sensor reading types. Valid values are:
| Assumed to be in cm, only 1 depth per sensor. | The brand of sensor. | The model of sensor. | ||
Data type | String | String | Decimal | Decimal | Specific strings | Decimal | String | String | String | String |
Required? | Required | Optional | Required | Required | Required | Optional | Optional | Optional | Optional | Optional |
Example | “Sensor 1” | “WERKTX” | -31.3624425 | -64.2104754448 | soil_water_content, soil_water_potential, temperature | 10 | “Ensemble Scientific” | “Model ABC” | “ESA-12345” | “B” |
Validation | 1 <= name.length <= 100 | 1 <= id.length <= 20 | -90 <= lat <= 90 | -180 <= long <= 180 | At least 1 of the following: soil_moisture_content, water_potential, temperature | 0 <= depth <= 1000 | String: < 100 length | String: < 100 length | String: < 100 length | String: < 100 length |
Error | “Invalid sensor name, must be between 1 and 100 characters” | “Sensor with external id: <id> already exists.” “Invalid external id, must be between 1 and 20 characters” | “Invalid latitude value, must be between -90 and 90. and fewer than 10 decimals” | “Invalid longitude value, must be between -180 and 180. and fewer than 10 decimals” | “Invalid reading type detected, valid values include:
| “Invalid depth, must be a decimal value between 0 and 1000.” | “Invalid brand, must be fewer than 100 characters.” | “Invalid model, must be fewer than 100 characters.” | “Invalid part_number, must be fewer than 100 characters.” | “Invalid hardware_version, must be fewer than 100 characters.” |
Notes | May need to group sensors with same / similar lat / long on the map. This should be default behaviour since sensors are points. For this project depths can be 10, 20, 30, 50. | If this is “Ensemble Scientific”, it should activate the need to register this sensor during the bulk creation endpoint. |
Definition of a sensor: A device with a single id, name, lat / long, and depth. Must have at least one reading parameter, but may have several. Optionally has a brand and model. Ensemble requires a part_number and hardware_version to register it with their service.
Validation should be performed at least via the API and potentially through the UI as well.
Architectural guidance
Please take this as guidance rather than instruction. The following tables seem to make sense to allow users to document sensors and to integrate them with those external services.
Sensor: The attributes describing the physical device and it’s location. This should somehow tie to a point location for that sensor.
sensor_parameter: The parameters that instruct LiteFarm on how to parse data read by the sensor but don’t change from reading to reading and also aren’t related to the physical nature of the sensor. May just be part of the sensor table!
sensor_reading: Readings from the sensor.
Sensor | ID | Name | Lat_long | Type | Depth | Elevation | … |
---|---|---|---|---|---|---|---|
Description | The sensor’s unique id. | How the sensor will be labelled in LiteFarm. | The latitude and longitude for the sensor, comma separated. | Valid values to begin are: | Assumed to be in cm, comma delimited if multiple depths. | The elevation of ground level at the location where the sensor is mounted. | |
Required? | Required | Required | Required | Required | Optional | Optional | |
Example | “Sensor 1” | -31.362442522541148, -64.21047544487595 |
sensor_parameter | ID | Sensor_id | parameter_number | Type | Parameter_measured | Unit | Min_value | Max_value |
---|---|---|---|---|---|---|---|---|
Description | Unique identifier | Reference to a specific sensor. | For sensors with multiple types, this parameter would define 1 specific type. | |||||
Required? | ||||||||
Example |
Sensor_reading | ID | Read_time | Transmit_time | Sensor_ID | sensor_parameter_id | Value |
---|---|---|---|---|---|---|
Description | A unique identifier for this reading. May have some meaning or traceability for Ensemble. | The timestamp when this reading was captured. | The timestamp when this reading was transmitted. | The sensor reporting the reading. | The calibration which instructs on how to interpret the value. Required since each sensor can have multiple types of readings, e.g. “Temperature” and “Moisture”. | The numerical value of the reading. |
Required? | Required | Required | Required | Required | Required | |
Example |
Questions:
How does LiteFarm get a non-expiring token from the Ensemble API?
Probably manually enter this into an “integrations” table to similar to how certifiers have a surveystack link. Ultimately up to ESCI and the owner of LF-2483.
Will LiteFarm need a different token for each organization or will one token allow us to access multiple organizations?
Ideally one token per farm, but may have one universal instead. To verify with ESCI team.
What are the valid types of sensor (reading) types to start with?
soil_water_content (derived)
soil_water_potential
temperature
parameter | parameter_number(s) | explanation |
---|---|---|
soil_water_content | Ask Morten! | |
soil_water_potential | Ask Morten! | |
temperature | Ask Morten! |
Mark says that parameter_number is dynamic from device to device. Will need to develop a strategy to make this consistent.
How do we link up sensor_reading_types with a depth via csv upload?
Each sensor will only have 1 depth. We may choose to display sensors with very similar lat / long and different depths as the same sensor via the UI - but they are different in terms of sensor reading types and readings.
How does ensemble tie a reading to a parameter when posting new sensor readings?
It appears to be based on “parameter_number”. Need to explore what exactly this means to ESCI.
"node_esid":"123", "sensor_data":[ { "sensor_esid":"124", "sensor_values":[ { "parameter_number":1, "raw_value":2.910, "timestamp":"2022-01-10T17:41:00+0800" }, { "parameter_number":1, "raw_value":2.110, "timestamp":"2022-01-10T17:41:00+0800" }, { "parameter_number":2, "raw_value":0.001938, "timestamp":"2022-01-10T17:41:00+0800" } ] ...
What is the format for registering an organization with ESCI?
https://documenter.getpostman.com/view/18529342/UVXeqchj#b3a26ae9-be68-42a4-ac92-ca8025e7008c (see POST Create an organization)
curl --location --request POST 'api.esci.io/organizations/' \ --header 'Content-Type: application/json' \ --data-raw '{ "name": "tes_org", "uuid": "76df1f72-6fb0-11ec-90d6-0242ac120003", "website_url": "http://test.com", "email": "orgemail@hotmail.com", "phone": "123-4567", "street_number": "12345", "street": "Easy Street", "city": "Vancouver", "postal": "A1B2C3", "state": "British Columbia", "country": "Canada" }'
Authenticated users can create an organization.
"name" is the only required field
The creator will automatically become the admin and member of organization
Preferred UUID for organization can be optionally specified. Otherwise it will be autogenerated
Returns an error if UUID incorrect or non-unique
What is the format for registering a callback address with ESCI?
https://documenter.getpostman.com/view/18529342/UVXeqchj#b3a26ae9-be68-42a4-ac92-ca8025e7008c (assumed to be POST Create organization webhook)
curl --location -g --request POST 'api.esci.io/organizations/{{organization_uuid}}/webhooks/' \ --data-raw '{ "url": "http://www.example.com", "authorization_header": "Bearer eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJ1c2VyX3BrIjoxLCJ0b2tlbl90eXBlIjoiYWNjZXNzIiwiY29sZF9zdHVmZiI6IuKYgyIsImV4cCI6MTIzNDU2LCJqdGkiOiJmZDJmOWQ1ZTFhN2M0MmU4OTQ5MzVlMzYyYmNhOGJjYSJ9.NHlztMGER7UADHZJlxNG0WSi22a2KaYSfd1SAuT7lU", "frequency": 15 } // Example json that webhook will post to the url // [ // { // "node_esid": "123", // "sensor_esid": "124", // "parameter_number": 1, // "unit": "ºC", // "time": [ // "02-09-2022, 22:53:52", // "02-09-2022, 22:54:07" // ], // "value": [ // 1, // 2 // ], // "validated": [ // false, // false // ] // }, // { // "node_esid": "123", // "sensor_esid": "124", // "parameter_number": 2, // "unit": "kPa", // "time": [ // "02-09-2022, 22:54:23" // ], // "value": [ // 3 // ], // "validated": [ // false // ] // } // ]'
Create webhook for organization
Will send a confirmation request in the form of an empty array to the url (with authorization if any) before being created
Webhooks automatically send any organization data between current time and the webhook's last transmit time based on the webhook's frequency as long as it is active. Will send an empty array if no new data
authorization_header is optional
frequency is in minutes
Errors
400_BAD_REQUEST
Invalid json, incorrect url
received Response other than 200_OK from url during creation
Errors when trying to send confirmation request to the url
Only organization admins can call
Do we need a different callback address for each organization or can the callback specify org as part of the hierarchy?
Does the callback only send what has happened since the last update? Is there a failsafe if a callback fails to communicate several rounds of data?
Yes, ESCI will keep track of what has been shared and only send updates.
What is the format for registering sensors with ESCI?
https://documenter.getpostman.com/view/18529342/UVXeqchj#b3a26ae9-be68-42a4-ac92-ca8025e7008c (assumed to be POST Add a new device)
curl --location --request POST 'api.esci.io/devices/' \ --data-raw '{ "part_number": "ESA-12345", "hardware_version": "B" } // example response.data // { // "esid": "GLMCHJ", // "device_type": { // "id": 1, // "name": "Temperature Pressure Sensor", // "part_number": "ESA-1001", // "device_category": "S" // }, // "hardware_version": "B", // "parameters": [ // { // "parameter_number": 1, // "category": "Temperature", // "unit": "ºC", // "label": "Area 1" // }, // { // "parameter_number": 2, // "category": "Soil Water Tension", // "unit": "kPa", // "label": "Area 2" // } // ] // } '
Adds device to cloud with the specified POST data:
part_number
hardware_version
Device ESID will automatically be generated and any device parameters will be created based on the DeviceType's default parameter list if it exists.
Any generated parameters will have a 1:1 calibration generated with it as well
If device is interfacer, sets configurable to TRUE, so users can modify the device with other APIs
Errors:
400_BAD_REQUEST
Device type with part_number does not exist
Any fields missing
Only ESci admins can call
What depths are the sensors at (for this project)?
10, 20, 30, and 50cm. Duplicates at 10 and 30.
Are there any attributes above that are missing?
What data types can we have for sensor reading values?
soil_water_content: Derived from water_potential and temperature
water_potential: Sensed
temperature: Sensed
Requirements
- LF-2338Getting issue details... STATUS
Summary | Description | Fix Version |
---|---|---|
Sensor model work | Build out database to support tables for:
| MVP |
Bulk or individual? | v2 | |
Upload screen with template and front-end validation | v1 | |